Uji Banding Antar-Laboratorium Terhadap Analisis Logam (Fe, Mn, Cu, Zn) dan Mikrobiologi (Escherichia coli dan Total Coliform) sebagai Indikator Kualitas Air Minum Isi Ulang
Abstract
Quality assurance is a fundamental requirement for testing laboratories to demonstrate technical competence and ensure the reliability of analytical results. One important quality assurance mechanism is participation in interlaboratory comparison schemes or proficiency testing. This study had two objectives: 1. To evaluate the quality of drinking water from refillable drinking water depots (DAMIU) in Jambi, 2. to evaluate the analytical competence of the Integrated Laboratory Academic Service Unit (UPA LT) at the University of Jambi in measuring the concentrations of metals (Mn, Fe, Cu, Zn) and microbiological parameters (Escherichia coli and total coliforms) in drinking water from DAMIU through comparison with three laboratories accredited to ISO/IEC 17025:2017. Drinking water samples were collected from ten DAMIUs in the City of Jambi. Metal and microbiological analyses of each sample were carried out by 1. Jambi Provincial Environmental Laboratory (LP 413 IDN); 2. Jambi City Environmental Laboratory (LP 1194 IDN); 3. PT Jambi Lestari International (LP 1129 IDN), and 4. Integrated Laboratory of the University of Jambi (UPA LT). All DAMIU samples met the metal concentration standards, but only Kotabaru and Alam Barajo DAMIU samples met the microbiological criteria. Laboratory performance was evaluated using Z-score analysis. The analysis of Cu and Zn showed satisfactory performance across all participating laboratories (|Z| ≤ 2.0), indicating consistent measurement precision and accuracy. However, the determination of Fe and Mn showed questionable Z-scores (2.0 < |Z| < 3.0) in some laboratories, indicating the presence of systematic bias or inconsistencies in calibration that require corrective action through proficiency testing protocols. Microbiological analysis presented more significant analytical challenges, yielding unacceptable Z-values (|Z| ≥ 3.0) at DLH9, JLI12, and JLI15. The high prevalence of microbiological contamination in drinking water from DAMIU highlights a significant public health issue in the City of Jambi. Only 20% of DAMIUs in Jambi City meet the drinking water quality standards. Based on the interlaboratory comparison, UPALT is now eligible for an expansion of its testing scope to include metals and microbes in drinking water.
Keywords
Full Text:
Logam Berat Air Minum Isi UlangReferences
Afrisetiawati. 2016. Identifikasi Bakteri Escherchia coli pada Air Minum Isi Ulang yang di Produksi Air Minum Depot Air Minum Isi Ulang di Kelurahan Lubuk Buaya Kota Padang.
http://scholar.unand.ac.id/id/eprint/12507. Fakultas Kedokteran Universitas Andalas, Padang.
BSN. 2009. SNI 6989.4-2009, Air dan air limbah – Bagian 4: Cara uji besi (Fe) secara Spektrofotmetri Serapan Atom (SSA)-nyala. Jakarta.
BSN. 2009. SNI 6989.5-2009, Air dan air limbah – Bagian 5: Cara uji mangan (Mn) secara Spektrofotmetri Serapan Atom (SSA)-nyala. Jakarta.
BSN. 2009. SNI 6989.6-2009, Air dan air limbah – Bagian 6: Cara uji tembaga (Cu) secara Spektrofotmetri Serapan Atom (SSA)-nyala. Jakarta.
BSN. 2009. SNI 6989.7-2009, Air dan air limbah – Bagian 4: Cara uji seng (Zn) secara Spektrofotmetri Serapan Atom (SSA)-nyala. Jakarta.
BSN. 2018. SNI ISO/IEC 17025:2017, Persyaratan umum kompetensi laboratorium pengujian dan kalibrasi. Jakarta.
Harjito. 2019. Evaluasi uji banding antar laboratorium untuk mengukur kompetensi personil. Universitas Gadjah Mada, Yogyakarta.
Keputusan Menteri Kesehatan RI no 97/Menkes/SK/VII/2002. Tentang Persyaratan Kualitas Air Minum.
Permenkes No. 492 Tahun 2010 tentang Persyaratan Kualitas Air Minum. Kemenkes, Jakarta.
Permenkes No. 43 Tahun 2014 tentang Hygiene Sanitasi Depot Air Minum. Kemenkes, Jakarta.
Permenkes No. 2 Tahun 2023 tentang Kesehatan Lingkungan. Kemenkes, Jakarta.
Purba, S. K., Handini, M. C., & Sirait, A. (2023). Determinan Keberadaan Bakteri E. coli pada Air Minum: Survei pada Depot Air Minum Isi Ulang (DAMIU) Kecamatan Medan Belawan, Kota Medan. JIKM, 15(4), 212–219.
Triwuri, N.A., Prasadi, O., & Wibowo, A. 2020. Analisis kandungan mangan (Mn) dan seng (Zn) pada air minum isi ulang. Jurnal Teknik Ibnu Sina 5(1): 45–52.
World Health Organization (WHO). 2017. Guidelines for drinking water quality. 4th edition. Geneva: WHO Press.
Zaid, G., Larassati, D., & Suherlan. 2001. Analisa hasil uji banding antar laboratorium nasional tingkat Asia Pasifik. Pusat Penelitian Kimia, LIPI.